A custom particle size analyzer system is designed to meet specific laboratory or industrial testing requirements that standard particle size analyzers cannot fully address. Customization may include automatic sampling, sample preparation, wet or dry dispersion, instrument integration, automated cleaning, data management, and communication with laboratory or production control systems.
Rather than modifying the core measurement technology unnecessarily, a customized solution typically integrates a suitable particle size analyzer with application-specific automation, control software, and sample-handling equipment.
Custom particle size analyzer systems can be designed for laboratory testing, production-line sampling, or automated process monitoring.
Customization may involve wet dispersion, dry powder feeding, automatic sampling, sample dilution, cleaning, and data integration.
Laser diffraction is commonly used when particle size distribution measurement across a broad size range is required.
Existing particle size analyzers can often be integrated into an automated workflow without replacing the entire instrument.
The right design depends on sample properties, measurement standards, throughput, cleaning requirements, and the level of automation required.
A successful custom solution should be validated against the application's measurement requirements before routine operation.
A custom particle size analyzer system is an application-specific measurement and automation solution developed around particular sample characteristics, testing procedures, and operational requirements.
A standard particle size analyzer generally provides the core measurement function. However, many laboratories and manufacturing facilities require additional operations before, during, and after measurement.
For example, a laboratory may need to automatically prepare multiple powder samples, while a battery materials manufacturer may need to collect slurry samples from several production lines and measure their particle size distributions.
These requirements can involve several integrated components:
| System Component | Function | Possible Customization |
|---|---|---|
| Particle size analyzer | Measures particle size distribution | Laser diffraction, image analysis, or other suitable measurement technologies |
| Sampling system | Collects representative samples | Manual, automatic, multi-point, or pipeline sampling |
| Sample preparation unit | Prepares samples for measurement | Dilution, mixing, dispersion, or ultrasonic treatment |
| Sample feeding system | Transfers samples to the analyzer | Automatic powder feeding or liquid transfer |
| Cleaning system | Removes residual samples | Water washing, solvent cleaning, or application-specific procedures |
| Control system | Coordinates equipment operations | PLC, industrial computer, or integrated control |
| Data management system | Stores and transfers measurement data | Database, laboratory software, DCS, or MES interfaces |
The objective is not simply to automate an instrument. It is to create a complete and repeatable particle size testing workflow.
A custom particle size analysis system may be appropriate when standard equipment cannot meet the required sample-handling, testing, or integration conditions.
Some materials require special handling before particle size measurement.
Examples include:
High-viscosity slurries
Agglomerated powders
Fine chemical powders
Battery electrode materials
Materials that are sensitive to moisture
Samples that require controlled dispersion
Materials with strict contamination-control requirements
For these applications, the sampling and pretreatment process may be just as important as the analyzer itself.
Laboratories that process large numbers of samples may benefit from automated sample loading, sample identification, measurement sequencing, and cleaning.
A customized system can reduce repetitive manual operations and help standardize the testing workflow.
However, the achievable throughput depends on the measurement method, sample preparation time, cleaning cycle, and number of analyzers.
Manufacturing processes may require particle size testing at different locations or production stages.
A customized sampling system can be designed to collect samples from multiple points and transfer them to a centralized measurement station.
This is particularly relevant to battery materials, chemical production, mineral processing, and other processes where particle size distribution is an important quality parameter.
Replacing an existing particle size analyzer may not always be necessary.
If the analyzer remains suitable for the required measurement method, an automation retrofit can add functions such as:
Automatic sample feeding
Automated sample transfer
Automatic liquid addition
Ultrasonic dispersion
Automatic cleaning
Instrument status monitoring
Centralized data collection
The feasibility of integration depends on the analyzer's communication interfaces, mechanical configuration, software access, and manufacturer specifications.
Customization should be based on the complete testing process rather than a single equipment specification.
The sampling system determines how material is collected and delivered for measurement.
Common options include:
| Sampling Type | Typical Application | Design Considerations |
|---|---|---|
| Manual sampling | Routine laboratory testing | Operator procedures and sample identification |
| Automatic bottle sampling | Multiple laboratory samples | Sample positioning and transfer |
| Pipeline sampling | Liquid or slurry process monitoring | Pressure, flow, material compatibility, and representative sampling |
| Multi-point sampling | Multiple production locations | Sampling sequence, line switching, and sample traceability |
| Online sampling | Continuous or frequent process monitoring | Process interface, sample conditioning, and maintenance |
Representative sampling is essential. A highly automated system cannot compensate for a sampling method that fails to collect material representative of the process.
Wet particle size analysis is commonly used for powders and materials that can be dispersed in a suitable liquid medium.
A customized wet dispersion system may include:
Liquid storage and supply
Automatic water or dispersant addition
Sample mixing
Ultrasonic dispersion
Circulation pumps
Flow control
Temperature monitoring
Automatic drainage and cleaning
The dispersion method must be selected according to the material's physical and chemical properties.
Excessive ultrasonic energy, for example, may break fragile particles and change the measured particle size distribution. Insufficient dispersion may leave agglomerates in the sample and produce misleading results.
For materials that are unsuitable for wet dispersion, dry dispersion may be considered.
A customized dry powder feeding unit may include:
Automatic powder dosing
Vibrating feeders
Hopper systems
Powder transfer mechanisms
Air pressure and flow regulation
Dust collection
Enclosed sample handling
The system should control feeding stability and dispersion conditions to improve measurement repeatability.
For cohesive, electrostatic, or moisture-sensitive powders, the feeding mechanism and environmental conditions require particular attention.
Residual material can affect subsequent measurements, especially when testing different materials or samples with significantly different particle size distributions.
A cleaning system may be designed around:
Water or solvent selection
Automatic flushing
Pipeline cleaning
Measurement-cell cleaning
Drainage
Drying, where necessary
Cleaning-cycle verification
Cleaning requirements should be established through contamination testing rather than assumed from the appearance of the equipment.
A custom particle size analyzer automation system may use a PLC, industrial computer, or a combination of control devices.
Typical software functions include:
Automatic testing sequence management
Sample ID and barcode management
Sampling-point selection
Instrument status monitoring
Alarm and fault records
Measurement data collection
Historical data queries
Report generation
Communication with DCS, MES, or laboratory information systems
The available functions depend on the analyzer's software interfaces and the integration requirements of the project.
The selection of wet or dry particle size analysis depends on the sample's physical properties and the measurement method.
| Comparison | Wet Particle Size Analysis | Dry Particle Size Analysis |
|---|---|---|
| Sample form | Powder dispersed in liquid, slurry, or suspension | Dry powder |
| Dispersion medium | Water or another suitable liquid | Compressed air or another dry dispersion mechanism |
| Main preparation | Mixing, dilution, wetting, ultrasonic dispersion | Feeding, deagglomeration, airflow control |
| Typical materials | Pigments, suspensions, ceramics, battery slurries | Minerals, cement, dry chemicals, powders |
| Main considerations | Liquid compatibility, dispersion stability, cleaning | Feeding stability, moisture, dust, agglomeration |
| Automation options | Liquid addition, circulation, sampling, washing | Powder dosing, feeding, air regulation, dust collection |
Neither method is universally better.
The selection should consider whether the measurement conditions can represent the material's actual application state. For example, a powder that dissolves or reacts in water may not be suitable for wet analysis.
A reliable customization project should begin with the testing requirements and process workflow.
Before equipment selection, establish:
Material name and composition
Sample physical state
Expected particle size range
Required measurement parameters
Applicable testing standards
Sample volume
Number of samples per day
Required measurement frequency
Repeatability and accuracy requirements
For laser diffraction applications, the required particle size distribution may include D10, D50, and D90.
These values represent the particle sizes below which 10%, 50%, and 90% of the measured distribution fall, respectively, based on the selected distribution basis.
Determine whether the material requires:
Drying or moisture control
Dilution
Mixing
Wetting
Ultrasonic dispersion
Deagglomeration
Temperature control
Special cleaning procedures
The preparation method should be validated to ensure that it does not unintentionally change the particle size distribution.
The measurement instrument should match the sample and application.
Potential technologies include:
| Measurement Technology | Typical Application |
|---|---|
| Laser diffraction | Particle size distribution measurement across a broad range |
| Dynamic image analysis | Particle size and shape characterization |
| Static image analysis | Image-based particle characterization |
| Sedimentation methods | Particle size analysis based on settling behavior |
The choice should be based on measurement range, sample properties, required output, testing standards, and method validation.
After selecting the measurement method, define how samples move through the system.
A typical automated wet particle size analysis workflow is:
Sample collection
Sample identification
Sample transfer
Liquid addition
Mixing and dispersion
Measurement
Data collection
Sample discharge
Cleaning
Preparation for the next sample
For production applications, the workflow may also include sampling-point switching, process communication, and abnormal-condition handling.
The integration design may include:
Analyzer communication
PLC control
Sensors and actuators
Pumps and valves
Industrial computer
Human-machine interface
Database
DCS or MES communication
Before implementation, define communication protocols, signal ownership, alarm logic, data formats, and system responsibilities.
A custom system should be evaluated using actual application materials.
Important validation items include:
| Validation Item | What to Check |
|---|---|
| Sampling representativeness | Whether collected samples reflect the process material |
| Measurement repeatability | Whether repeated measurements produce consistent results |
| Dispersion suitability | Whether preparation conditions affect particle integrity or agglomeration |
| Cleaning effectiveness | Whether residual contamination is controlled |
| Workflow reliability | Whether automatic sequences operate as intended |
| Data integrity | Whether results are correctly identified, stored, and transferred |
| Safety | Whether moving parts, chemicals, pressure, and waste are properly managed |
Acceptance criteria should be agreed upon before commissioning.
Custom particle size analysis and automation are relevant to several industries.
Particle size distribution is an important characterization parameter for battery materials and electrode slurries.
Depending on the material and process stage, customized systems may support:
Cathode material testing
Anode material testing
LFP slurry particle size analysis
Slurry sampling from multiple production points
Wet dispersion and laser diffraction measurement
Measurement data transfer to production systems
For slurry applications, sampling location, sample homogeneity, dilution, dispersion energy, and cleaning procedures must be carefully controlled.
Chemical manufacturers may require particle size monitoring for pigments, fillers, catalysts, and other particulate materials.
Customized automation can support sample preparation, measurement sequencing, and centralized data management.
Particle size can influence powder flowability, dissolution behavior, blending, and product consistency.
The testing system should be designed according to the material's properties and the relevant analytical procedures.
For regulated applications, equipment qualification, cleaning documentation, data integrity, and method validation may also be required.
Minerals, cement, and other construction materials may require dry or wet particle size analysis.
A customized system can automate powder feeding, sample transfer, dispersion, and measurement-data collection according to the production or laboratory workflow.
The following example is an engineering design illustration based on a published Exceed Testing technical solution. It describes the proposed system configuration, not independently verified production performance.
In lithium iron phosphate (LFP) battery material production, particle size analysis may be required during the fine grinding stage.
A multi-line production process creates a challenge: samples need to be collected from different locations, prepared under consistent conditions, measured, and associated with the correct production point.
Manual sampling and testing can involve repeated operator handling and data recording.
The published Exceed technical scheme describes the following design conditions:
| Item | Proposed Configuration |
|---|---|
| Material | LFP slurry |
| Process stage | Fine grinding |
| Production layout | 8 production lines |
| Fine grinding equipment | 4 units per production line |
| Particle size analyzers | 2 units planned |
| Sampling | Automatic multi-point sampling |
| Sample preparation | Automatic water addition and ultrasonic pre-dispersion |
| Measurement | Wet laser diffraction |
| Control | PLC, valves, and upper-level control software |
| Production communication | DCS/MES communication according to project interface requirements |
| Analyzer model in the proposal | FRITSCH A22 NeXT Nano |
The technical scheme indicates approximately 3–4 minutes of measurement time per sampling point. This is not the complete system cycle time. Actual cycle time must also account for sample transfer, line switching, cleaning, repeat measurements, and other process operations.
Select a production sampling point.
Collect the LFP slurry sample automatically.
Transfer the sample to the preparation unit.
Add water according to the configured procedure.
Apply ultrasonic pre-dispersion.
Transfer the prepared sample to the laser diffraction analyzer.
Collect particle size measurement data.
Associate the result with the relevant sampling point.
Clean the sample-contact components before the next measurement.
Several factors should be evaluated during detailed design:
Whether the sample collection method provides representative slurry samples
Whether dilution changes the measurement conditions
Whether ultrasonic treatment causes particle breakage
Whether the pipeline and valves are compatible with the slurry
Whether cleaning can prevent cross-contamination
Whether the analyzer supports the required communication interface
Whether two analyzers can meet the required sampling frequency
This type of project demonstrates why a custom particle size analysis system needs coordinated design across sampling, preparation, measurement, control, and data integration.
In many cases, an existing analyzer can be integrated into a customized automation system.
This approach may be suitable when the current instrument still meets the required measurement range, accuracy, and testing method.
Possible retrofit functions include:
Automatic sample loading
Automatic liquid addition
Automated dispersion
Automatic measurement triggering
Sample transfer and positioning
Automatic cleaning
Data collection
Centralized control
However, not every analyzer can support every automation function.
Before selecting a retrofit solution, engineers should evaluate:
Analyzer model and manufacturer.
Available communication protocols.
Whether external control is supported.
Available mechanical access and connection points.
Software permissions and integration limitations.
Warranty and maintenance implications.
Required measurement and safety validation.
A retrofit feasibility assessment should be completed before finalizing the system design.
| Comparison | Standard Particle Size Analyzer | Custom Particle Size Analyzer System |
|---|---|---|
| Main purpose | Individual particle size measurement | Application-specific measurement workflow |
| Sample handling | Often manual or instrument-specific | Can include automatic sampling and transfer |
| Sample preparation | Standard or manually configured | Can be customized for the material |
| Cleaning | Instrument-dependent | May include additional automatic cleaning |
| Multiple sampling points | Usually requires additional handling or equipment | Can be designed into the workflow |
| Production integration | Depends on instrument interfaces | Can include PLC, DCS, or MES integration |
| Implementation | Generally simpler | Requires application analysis and engineering |
| Flexibility | Based on standard instrument functions | Based on project requirements and technical feasibility |
A customized system is not automatically the best option for every laboratory.
For low sample volumes and straightforward testing procedures, a standard analyzer may be more economical. Customization becomes more valuable when the sample-handling process, testing frequency, or integration requirements are complex.
Choosing a supplier requires evaluating both measurement expertise and system integration capabilities.
Consider the following factors:
The supplier should understand the measurement principles, sample preparation requirements, and limitations of the selected analyzer.
Ask whether the engineering team can design sampling, feeding, transfer, dispersion, and cleaning systems for your material.
The supplier should be able to assess communication interfaces and coordinate integration with the selected analyzer.
Check whether the supplier can provide PLC control, industrial software, data management, and communication with existing production systems.
A complete project should include workflow testing, measurement verification, cleaning evaluation, and acceptance against agreed requirements.
Confirm the availability of technical documentation, spare parts, maintenance, software support, and troubleshooting services.
Exceed Testing focuses on laboratory automation system integration and customized testing workflows.
Its particle size analyzer automation solutions can be developed around project-specific requirements, including:
Particle size analyzer automation
Wet laser particle size analysis automation
Automatic sample preparation
Multi-point sampling systems
Automated liquid handling
PLC-based equipment control
Laboratory instrument integration
DCS/MES communication based on project requirements
The appropriate configuration depends on the material, analyzer model, sampling frequency, laboratory workflow, and production interface.
For projects involving existing instruments, the feasibility of automation retrofit can also be evaluated before deciding whether new equipment is necessary.
Explore related solutions:
Particle Size Analyzer Automation: https://www.exceed-testing.com/ypqclzdh
Laboratory Automation Solutions: https://www.exceed-testing.com/news/41
Smart Laboratory Automation System Integration: https://www.exceed-testing.com/news/40
LFP Slurry Particle Size Automation Case: https://www.exceed-testing.com/news/43
Exceed Testing Company Profile: https://en.exceed-testing.com/about
A custom particle size analyzer system is an application-specific solution that combines a suitable measurement instrument with customized sampling, sample preparation, feeding, cleaning, control, and data integration functions.
Yes. The sampling and preparation workflow can be designed according to the material's properties, including viscosity, moisture sensitivity, agglomeration, dispersion behavior, and chemical compatibility.
In many cases, yes. External automation may be added for sample loading, liquid addition, dispersion, cleaning, and data collection. Feasibility depends on the analyzer's mechanical and communication interfaces.
Wet analysis disperses particles in a suitable liquid medium, while dry analysis uses a gas or air-based dispersion process. The appropriate method depends on material properties and the intended measurement procedure.
It may be possible when the analyzer and control system provide compatible communication interfaces. The required protocol, data structure, signal mapping, and security requirements should be confirmed during engineering design.
Project duration depends on the complexity of sampling, preparation, mechanical design, software development, instrument integration, manufacturing, and validation. A timeline should be established after reviewing the technical requirements.
Typical information includes material characteristics, sample form, particle size range, testing frequency, number of sampling points, existing analyzer model, automation requirements, and desired communication interfaces.
It can be suitable when the sampling, dilution, dispersion, and measurement procedures are validated for the specific slurry. Special attention should be paid to sample representativeness, particle stability, and cleaning.
No. If an existing instrument meets the measurement requirements and supports the necessary interfaces, it may be integrated into a customized automation system.
A project may include the analyzer, sampling equipment, sample preparation unit, transfer mechanisms, cleaning system, control hardware, software, data integration, commissioning, and validation documentation.
A custom particle size analyzer system should be designed around the complete measurement workflow rather than the analyzer alone.
For laboratories and manufacturers with complex sample characteristics, multiple sampling points, high testing frequency, or production data integration requirements, customization can help connect sampling, preparation, measurement, cleaning, and data management into a coordinated process.
The most suitable solution depends on the material, measurement method, existing equipment, and required level of automation. A detailed application assessment and validation plan should therefore be completed before equipment selection and system implementation.
Custom Particle Size Analyzer Systems: Design, Integration, and Applications
2026.11.06
Particle Size Analyzer Automation Retrofit: How to Automate Existing Equipment
2026.11.06
Automated Laboratory Sample Transfer System: Design, Workflow & Applications
2026.11.05
Automated Particle Size Analysis System: How It Works, Applications, and Real-World Design
2026.11.05Copyright © Zhejiang Qibiao Intelligent Laboratory Technology Co., Ltd. All Rights Reserved.Zhejiang ICP No. 2024131427-1